Circuit of regulation of mixtureInputs:

  • 4x thermocouple
  • 2x lambda sensor unit
  • 1x PT100
  • 1x servo location
  • 2x differential current (voltage) input 0..20mA (0..10V)
  • 8 binary inputs
  • measurement of rotation

Outputs: 

  • 1x servo 230V AC
  • 1x stepping motor 24V/0,1-0,5 A (micro - stepping)

Supplying voltage 10-33 VDC 